高级检索
当前位置: 首页 > 详情页

Assessment of radiation dose and iodine load reduction in head-neck CT angiography using two scan protocols with wide-detector

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, 212 Yuhua Rd, Baoding 300072, Hebei, Peoples R China [2]Hebei Univ, Coll Med, Baoding, Peoples R China
出处:
ISSN:

关键词: Gemstone spectral imaging radiation dose image quality low iodine intake head-neck CT angiography

摘要:
OBJECTIVE: To compare image quality, radiation dose, and iodine intake of head-neck CT angiography (CTA) acquired by wide-detector with the gemstone spectral imaging (GSI) combination with low iodine intake or routine scan protocol. METHODS: Three hundred patients who had head-neck CTA were enrolled and divided into three groups according to their BMI values: group A (18.5 kg/m(2) <= BMI <24.9 kg/m(2)), group B (24.9 kg/m(2) <= BMI <29.9 kg/m(2)) and group C (29.9 kg/m(2) <= BMI <= 34.9 kg/m(2)) with 100 patients in each group. Patients in each group were randomly divided into two subgroups (n = 50) namely, A1, A2, B1, B2, C1 and C2. The patients in subgroups A1, B1 and C1 underwent GSI with low iodine intake (270 mgI/ml, 50 ml) and combined with the ASiR-V algorithm. Other patients underwent three dimensional (3D) smart mA modulation with routine iodine intake (350 mgI/ml, 60 ml). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated after angiography. Images were then subjectively assessed using a 5-point scale. CT dose index of volume and dose-length product (DLP) was converted to the effective dose (ED) and then compared. RESULTS: The mean CT values, SNR, CNR and subjective image quality in subgroups A2, B2 and C2 are significantly lower than in subgroups A1, B1, and C1 (P < 0.01), respectively. The ED values in subgroup A1, B1, and C1 are 55.18%, 61.89%, and 69.64% lower than those in A2, B2, and C2, respectively (P < 0.01). The total iodine intakes in subgroups A1, B1, and C1 are 35.72% lower than those in subgroups A2, B2, and C2. CONCLUSIONS: The gemstone spectral imaging with monochromatic images at 53-57 keV combined with ASiR-V algorithm allows significant reduction in iodine load and radiation dose in head-neck CT angiography than those yielded in routine scan protocol. It also enhances signal intensity of head-neck CTA and maintains image quality.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
JCR分区:
出版当年[2019]版:
Q3 PHYSICS, APPLIED Q3 INSTRUMENTS & INSTRUMENTATION Q4 OPTICS
最新[2023]版:
Q3 INSTRUMENTS & INSTRUMENTATION Q3 OPTICS Q3 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, 212 Yuhua Rd, Baoding 300072, Hebei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

[1]Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose [2]Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography [3]Comparative analysis of radiation dose and image quality between organ dose modulation and 3D smart mA modulation during head-neck CT angiography [4]不同扫描模式在头颈CT血管成像检查中图像质量与辐射剂量的比较研究 [5]CT angiography of the kidney using routine CT and the latest Gemstone Spectral Imaging combination of different noise indexes: image quality and radiation dose [6]A feasibility study of different GSI noise indexes and concentrations of contrast medium in hepatic CT angiography of overweight patients: image quality, radiation dose, and iodine intake [7]A Comparison of the Image Quality and Radiation Dose With Routine Computed Tomography and the Latest Gemstone Spectral Imaging Combination of Different Scanning Protocols in Computed Tomography Angiography of the Kidney [8]新宝石能谱成像联合不同噪声指数和常规扫描在肾动脉cta中影像质量和辐射剂量的比较研究 [9]CT pulmonary angiography using organ dose modulation with an iterative reconstruction algorithm and 3D Smart mA in different body mass indices: image quality and radiation dose [10]CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose

资源点击量:15100 今日访问量:4 总访问量:960 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号