高级检索
当前位置: 首页 > 详情页

CT angiography of the kidney using routine CT and the latest Gemstone Spectral Imaging combination of different noise indexes: image quality and radiation dose

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, 212 Yuhua East Rd, Baoding City 071000, Peoples R China
出处:
ISSN:

关键词: Gemstone Spectral Imaging Noise index Adaptive statistical iterative reconstruction 2 0 Radiation dose Image quality CT angiography of the kidney

摘要:
Objective The objective of our study was to compare the image quality and radiation dose of computed tomography angiography (CTA) of the kidney in patients with different body mass indexes using routine CT and the latest Gemstone Spectral Imaging (GSI) combination of different noise indexes (NI) with the adaptive statistical iterative reconstruction 2.0 algorithm (ASiR 2.0). Methods A total of 120 patients who had undergone a CTA of the kidney were divided into four groups (A, B, C and D), with 30 patients in each group. Group A underwent a routine CT examination, while groups B, C and D underwent GSI with different noise indexes. All images were restructured using ASiR 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated when the kidney CTA was completed. Each subjective image evaluation used a 5-point scoring method and was conducted by two independent radiologists. The CT dose index of volume (CTDIvol) and dose-length product (DLP) were recorded, and the mean value was calculated. The DLP was converted to the effective dose (ED). All data were compared with one-way ANOVA. Results The SNR, CNR and subjective image quality in group A were significantly lower than in groups B, C and D (P < 0.01). There were no significant differences in SNR, CNR and subjective image quality among groups B, C and D. The ED of group D decreased by 47.81 and 18.59% relative to groups A and B, respectively (P < 0.01). Conclusion The latest GSI with different NI values can more effectively reduce the radiation dose than can the routine CT scan mode for a kidney CTA while still maintaining diagnostic image quality.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2017]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, 212 Yuhua East Rd, Baoding City 071000, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

[1]A Comparison of the Image Quality and Radiation Dose With Routine Computed Tomography and the Latest Gemstone Spectral Imaging Combination of Different Scanning Protocols in Computed Tomography Angiography of the Kidney [2]新宝石能谱成像联合不同噪声指数和常规扫描在肾动脉cta中影像质量和辐射剂量的比较研究 [3]CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose [4]肾动脉CT血管成像中采用常规扫描和能谱成像扫描方案对图像质量和辐射剂量的影响 [5]Assessment of radiation dose and iodine load reduction in head-neck CT angiography using two scan protocols with wide-detector [6]A Comparison of the Image Quality and Radiation Dose Using 100-kVp Combination of Different Noise Index and 120-kVp in Computed Tomography Pulmonary Angiography [7]CT pulmonary angiography using different noise index values with an iterative reconstruction algorithm and dual energy CT imaging using different body mass indices: Image quality and radiation dose [8]A feasibility study of different GSI noise indexes and concentrations of contrast medium in hepatic CT angiography of overweight patients: image quality, radiation dose, and iodine intake [9]Noise indices adjusted to body mass index and an iterative reconstruction algorithm maintain image quality on low-dose contrast-enhanced liver CT [10]肺动脉ct成像中不同扫描模式对影像质量及辐射剂量影响的对比研究

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号