A Comparison of the Image Quality and Radiation Dose With Routine Computed Tomography and the Latest Gemstone Spectral Imaging Combination of Different Scanning Protocols in Computed Tomography Angiography of the Kidney

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, Baoding, Peoples R China [2]Hebei Univ, Sch Med, Baoding, Peoples R China [3]Tianjin Univ, Sch Life Sci, Sch Precis Instrument & Optoelect Engn, Tianjin, Peoples R China
出处:
ISSN:

关键词: gemstone spectral imaging CT scan mode adaptive statistical iterative reconstruction 2 0 radiation dose image quality CT angiography of the kidney

摘要:
Objective: The objective of our study was to compare the image quality and radiation dose of computed tomography angiography (CTA) of the kidney in patients with different body mass indexes using routine CT and the latest gemstone spectral imaging (GSI) combination of different scanning protocolswith the adaptive statistical iterative reconstruction 2.0 algorithm. Methods: A total of 90 patients who had undergone a CTA of the kidney were divided into 3 groups (A, B, and C), with 30 patients in each group. Group A underwent a routine CT examination, whereas groups B and C underwent GSI with different scanning protocols. All images were restructured using the adaptive statistical iterative reconstruction 2.0. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all imageswere calculated when the kidney CTAwas completed. Each subjective image evaluation used a 5-point scoringmethod and was conducted by 2 independent radiologists. The CT dose index of volume and the dose-length product were recorded, and the mean value was calculated. The dose-length product was converted to the effective dose. All data were compared with a 1-way analysis of variance. Results: The SNR, CNR, and subjective image quality in group A were significantly lower than those in groups B and C (P < 0.01). There were no significant differences in SNR, CNR, and subjective image quality between groups B and C. The effective dose of group C decreased by 46.05% and 15.03% relative to those of groups A and B, respectively (P < 0.01). Conclusions: The latest GSI with different scanning protocols can more effectively reduce the radiation dose than can the routine CT scanmode for a kidney CTA while still maintaining diagnostic image quality.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2017]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, Baoding, Peoples R China [*1]Hebei Univ, Affiliated Hosp, Dept Radiol, Baoding City 071000, Hebei, Peoples R China
通讯作者:
通讯机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, Baoding, Peoples R China [*1]Hebei Univ, Affiliated Hosp, Dept Radiol, Baoding City 071000, Hebei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15679 今日访问量:0 总访问量:1035 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题