高级检索
当前位置: 首页 > 详情页

CT pulmonary angiography using organ dose modulation with an iterative reconstruction algorithm and 3D Smart mA in different body mass indices: image quality and radiation dose

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, 212 Yuhua Rd, Baoding City 300072, Hebei, Peoples R China
出处:
ISSN:

关键词: Organ dose modulation 3D Smart mA modulation Radiation dose Image quality CT pulmonary angiography

摘要:
To investigate the differences in imaging quality and radiation dose in CT pulmonary angiography (CTPA) by organ dose modulation and 3D Smart mA modulation in different body mass indices (BMIs) with an adaptive statistical iterative reconstruction (ASiR-V) algorithm. Three hundred female patients who underwent CTPA were equally divided into three groups: A (18.5 kg/m(2) ae broken vertical bar BMI < 24.9 kg/m(2)), B (24.9 kg/m(2) ae broken vertical bar BMI < 29.9 kg/m(2)) and C (29.9 kg/m(2) ae broken vertical bar BMIae broken vertical bar 34.9 kg/m(2)). The groups were randomly subdivided into two subgroups (n = 50): A1-A2, B1-B2 and C1-C2. The patients in subgroups A1, B1 and C1 underwent organ dose modulation with the ASiR-V algorithm. The other patients underwent 3D Smart mA modulation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all images were calculated after CTPA. Images were then subjectively evaluated using a 5-point scale. The volume CT dose index and dose-length product (DLP) were recorded and their means calculated. The DLP was converted to the effective dose (ED). In group A, the SNR, CNR, and subjective image scores showed no statistical differences (P > 0.05). The ED in subgroup A1 was 33.36% lower than that in A2. In group B and C, the variables showed no significant differences between the subgroups B1 and B2 (P > 0.05), and the subgroups C1 and C2 (P > 0.05), respectively. The ED in subgroup B1 and C1 was 36.15 and 38.22% lower than that in B2 and C2, respectively. Using organ dose modulation and applying the ASiR-V algorithm can more effectively reduce the radiation dose in CTPA than in 3D Smart mA modulation, while maintaining image quality.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2018]版:
Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2024]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2024版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Hebei Univ, Affiliated Hosp, Dept Radiol, 212 Yuhua Rd, Baoding City 300072, Hebei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:19604 今日访问量:0 总访问量:1147 更新日期:2025-08-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号