Application of full-field organ dose modulation on cervical- thoraco-abdominopelvic contrast-enhanced computed tomography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Peoples R China [2]Baoding 2 Hosp, Dept Radiol, Baoding 071000, Peoples R China
出处:
ISSN:

关键词: Organ dose modulation Enhanced ct Image quality Radiation dose

摘要:
Background and objective To study the radiation dose and image quality on the use of full-field organ dose modulation (ODM) on cervical-thoracic-abdominal-pelvic contrast-enhanced computed tomography (CT) scanning on female chemotherapy patients. Methods Eighty female chemotherapy patients undergoing cervical-thoracic-abdominal-pelvic contrast-enhanced CT were prospectively enrolled and randomly divided into two groups: group A and group B, each with 40 patients. Full-field ODM technique was used on group A and regular scanning patterns were used on group B. We calculated and recorded the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective scores, mean tube currents of the anterior, left, posterior, and right aspects of the thyroid, breast, and ovary layers of all the images. The CT dose index volume (CTDIvol) and dose-length product (DLP) of each patient were recorded and the effective radiation dose (ED) was calculated. The above data were statistically analyzed. Results There were no statistically significant differences in the SNR, CNR, and image quality scores of the thyroid, breast, and ovary layers of groups A and B during the arterial and venous phases (P > 0.05). The tube current on the anterior, left, posterior, and right aspects of the thyroid, breast, and ovary layers during the arterial and venous phases (thyroid: 324.46 +/- 53.2 and 327.97 +/- 61.34; breast: 243.13 +/- 50.04 and 248.32 +/- 60.33; ovary: 332.28 +/- 71.50 and 339.78 +/- 76.69; respectively) of group A were (statistically) significantly lower than those of group B (thyroid: 407.60 +/- 96.81 and 402.73 +/- 90.15; breast: 313.00 +/- 106.68 and 315.20 +/- 106.73; ovary: 457.78 +/- 106.56 and 459.63 +/- 106.27; respectively) (P < 0.05). The respective mean CTDIvol and DLP in group A were 22% and 24% lower than those of group B. The mean EDs of the neck, chest, and abdominal-pelvic region in group A were 19.3%, 21.4%, and 26.4% lower than those of group B, respectively (P < 0.05). Conclusion The use of ODM can reduce radiation dose of female chemotherapy patients undergoing cervical-thoracic-abdominal-pelvic contrast-enhanced CT, especially radiation-sensitive organs, while maintaining overall image quality.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2021]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号