高级检索
当前位置: 首页 > 详情页

Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Hebei, Peoples R China [2]Hebei Univ, Baoding, Hebei, Peoples R China
出处:
ISSN:

关键词: GSI scan protocol head-neck CTA image quality radiation dose assessment

摘要:
OBJECTIVES: To compare image quality and radiation dose of computed tomography angiography (CTA) of the head and neck in patients using two Gemstone Spectral Imaging (GSI) scanning protocols. METHODS: A total of 100 patients who underwent head-neck CTA were divided into two groups (A and B) according to the scanning protocols, with 50 patients in each group. The patients in group A underwent GSI scanning protocol 1 (GSI profile: head and neck CTA), while those in group B underwent GSI scanning protocol 2 (GSI profile: chest 80 mm). All images were reconstructed using 40% and 70% pre- and post-adaptive level statistical iterative reconstruction V (pre-ASiR-V and post-ASiR-V) algorithms, respectively. The CT dose index (CTDIvol) and dose-length (DLP) product were recorded and the mean value was calculated and converted to the effective dose. CT values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of all images were calculated. Additionally, subjective image evaluation was conducted by two independent radiologists using a five-point scoring method. All data were statistically analyzed. RESULTS: There were no significant differences in the CT values, SNR, CNR, and subjective score between groups A and B (p > 0.05); however, the mean effective dose (1.2 +/- 0.1 mSv) in group B was 45.5% lower than that in group A (2.2 +/- 0.2 mSv) (p < 0.05). CONCLUSIONS: GSI scanning protocol 2 could more effectively reduce the radiation dose in head-neck CT angiography while maintaining image quality compared to GSI scanning protocol 1.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 仪器仪表 3 区 光学 3 区 物理:应用
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
JCR分区:
出版当年[2022]版:
Q2 INSTRUMENTS & INSTRUMENTATION Q2 OPTICS Q2 PHYSICS, APPLIED
最新[2023]版:
Q3 INSTRUMENTS & INSTRUMENTATION Q3 OPTICS Q3 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Hebei, Peoples R China
通讯作者:
通讯机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Hebei, Peoples R China [*1]Department of Radiology, the Affiliated Hospital of Hebei University, Baoding, Hebei Province 071000, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号