OBJECTIVES: To compare image quality and radiation dose of computed tomography angiography (CTA) of the head and neck in patients using two Gemstone Spectral Imaging (GSI) scanning protocols. METHODS: A total of 100 patients who underwent head-neck CTA were divided into two groups (A and B) according to the scanning protocols, with 50 patients in each group. The patients in group A underwent GSI scanning protocol 1 (GSI profile: head and neck CTA), while those in group B underwent GSI scanning protocol 2 (GSI profile: chest 80 mm). All images were reconstructed using 40% and 70% pre- and post-adaptive level statistical iterative reconstruction V (pre-ASiR-V and post-ASiR-V) algorithms, respectively. The CT dose index (CTDIvol) and dose-length (DLP) product were recorded and the mean value was calculated and converted to the effective dose. CT values, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of all images were calculated. Additionally, subjective image evaluation was conducted by two independent radiologists using a five-point scoring method. All data were statistically analyzed. RESULTS: There were no significant differences in the CT values, SNR, CNR, and subjective score between groups A and B (p > 0.05); however, the mean effective dose (1.2 +/- 0.1 mSv) in group B was 45.5% lower than that in group A (2.2 +/- 0.2 mSv) (p < 0.05). CONCLUSIONS: GSI scanning protocol 2 could more effectively reduce the radiation dose in head-neck CT angiography while maintaining image quality compared to GSI scanning protocol 1.
基金:
Key R& D projects of Hebei Province [20377765D]; Hebei province program of training and basic project of clinical medicine of China [361007]; Medical Science Foundation of Hebei University [2021A10, 2021X06]; Affiliated Hospital of Hebei University Outstanding Youth Foundation [2015Q002, 2015Q017]
第一作者机构:[1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Hebei, Peoples R China
通讯作者:
通讯机构:[1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding 071000, Hebei, Peoples R China[*1]Department of Radiology, the Affiliated Hospital of Hebei University, Baoding, Hebei Province 071000, China
推荐引用方式(GB/T 7714):
Zhang Tianle,Zhao Sai,Liu Yiwen,et al.Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose[J].JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY.2022,30(4):689-696.doi:10.3233/XST-221181.
APA:
Zhang, Tianle,Zhao, Sai,Liu, Yiwen,Liu, Zhichao,Ma, Zepeng...&Zhao, Yongxia.(2022).Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose.JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY,30,(4)
MLA:
Zhang, Tianle,et al."Comparison of two different GSI scanning protocols in head and neck CT angiography: Image quality and radiation dose".JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 30..4(2022):689-696