CT Pulmonary Angiography Using Automatic Tube Current Modulation Combination with Different Noise Index with Iterative Reconstruction Algorithm in Different Body Mass Index: Image Quality and Radiation Dose

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Affiliated Hosp Hebei Univ, Dept Radiol, 212 Yuhua East Rd Baoding City Hebei Prov, Baoding 071000, Peoples R China [2]Hebei Univ, Sch Med, Baoding 071000, Peoples R China [3]Tianjin Univ, Sch Life Sci, Tianjin 300072, Peoples R China
出处:
ISSN:

关键词: Automatic tube current modulation noise index radiation dose image quality CT pulmonary angiography

摘要:
Rationale and Objectives: This study aimed to determine the appropriate body mass index (BMI)-dependent noise index (NI) setting in computed tomography pulmonary angiography (CTPA) with automatic tube current modulation with adaptive statistical iterative reconstruction (ASiR). Materials and Methods: A total of 480 patients who had a CTPA were divided into group A (18.5 kg/m(2) <= BMI < 25 kg/m(2)), group B (25 kg/m(2) <= BMI < 30 kg/m(2)), and group C (BMI >= 30 kg/m(2)), according to their BMI values; each group had 160 patients. The three groups were further randomly divided into four subgroups: A1, A2, A3, A4; B1, B2, B3, B4; and Cl, C2, C3, C4, with corresponding NI values of 26, 36, 40, and 46, respectively. All images were restructured with the ASiR algorithm, and the images with the lowest NI (26 Hounsfield units) in each group were used as reference standard. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for the pulmonary artery of each group were calculated. Subjective image quality was evaluated using a five-score method by two independent radiologists. The CT dose index of volume and dose-length product were recorded and were converted to effective dose (ED). SNR and CNR in the group A, B, and C subgroups were compared to repeated measures analysis of variance, and the subjective score, Volumetric CT dose index of volume, dose-length product, and ED were compared to one-way analysis of variance. Results: For groups A and B, the SNR, CNR, and subjective scores of the images in their subgroups showed no statistical differences (P >.05). The ED in subgroups A4 and B4 was significantly lower than that in subgroups Al (by 33.24%) and B1 (by 34.47%) (P <.01). For group C, there was no significant difference in the SNR, CNR, and the subjective image scores between subgroups C3 and Cl (P >.05). The ED in subgroup C3 was significantly lower than the ED in subgroup Cl (by 47.75%) (P <.01) Conclusions: Patient BMI-dependent NI settings that are higher than the recommended value may be used in CTPA with automatic tube current modulation and ASiR to effectively reduce radiation dose while maintaining diagnostic image quality.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2016]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Affiliated Hosp Hebei Univ, Dept Radiol, 212 Yuhua East Rd Baoding City Hebei Prov, Baoding 071000, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:4 总访问量:960 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号