高级检索
当前位置: 首页 > 详情页

A feasibility study of different GSI noise indexes and concentrations of contrast medium in hepatic CT angiography of overweight patients: image quality, radiation dose, and iodine intake

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, 212 Yuhua Rd, Baoding 071000, Hebei, Peoples R China
出处:
ISSN:

关键词: Low concentration of contrast medium Noise index Image quality Radiation dose Iodine intake

摘要:
Purpose To conduct a comparative study of image quality, radiation dose, and iodine intake in hepatic computed tomographic angiography (CTA) of overweight patients with different Gemstone Spectral Imaging (GSI) noise indexes combined with different concentrations of contrast medium.Materials and methods Ninety patients with a body mass index of >= 25 kg/m(2 )were divided into three groups (A, B and C), each with 30 patients. The three groups underwent hepatic CTA with different NI of 7, 11 and 15, respectively, and were injected with different iodine concentrations of 370, 350 and 320 mgI/mL, respectively. Five sets of images at 40-60 keV (interval, 5 keV) were reconstructed in each group. The CT value, image noise, contrast-to-noise ratio (CNR) and subjec-tive score of the hepatic artery and vein, and portal vein in different monochromatic image sets were analyzed to select the optimal energy level in each group. The differences in CT value, image noise, CNR and a subjective score of hepatic artery and vein, portal vein in the optimal monochromatic images among the three groups were compared, the volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded, and the effective dose and iodine intake were calculated.Results The 40 keV was determined to be the optimal energy level for the monochromatic image sets in each group. No significant group differences were noted in the CT value, image noise, CNR, and subjective image scores of the hepatic artery and vein, and portal vein for the optimal monochromatic images (P > 0.05). Compared with group A, the effective dose and iodine intake in group B were reduced by 50.18% and 9.3%, and by 58.12% and 14.23% in group C, respectively.Conclusion A low-concentration contrast medium combined with a high-noise GSI index in hepatic CTA of overweight patients can reduce the radiation dose and iodine intake while ensuring image quality.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, 212 Yuhua Rd, Baoding 071000, Hebei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号