Optimizing the image quality of peripancreatic blood vessels through the clinical application of single-energy spectral computed tomography (CT) imaging

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Affiliated Hospital of Hebei University, Baoding, China. [2]Department of Radiology, Renji Hospital Shanghai Jiaotong University School of Medicine, Shanghai, China.
出处:
ISSN:

关键词: Angiography optimal energy computed tomography (CT) X-ray

摘要:
With the increase of pancreatic tumor patients in recent years, there is an urgent need to find a way to treat pancreatic tumors. Surgery is one of the best methods for the treatment of pancreatic tumors, the success of which depends on the evaluation of peripancreatic vessels before surgery. Computed tomography (CT), as a non-invasive, fast, and economical auxiliary examination method, is undoubtedly one of the best means of clinical auxiliary examination. In this study, we investigated the impact of single-energy spectral CT imaging on the image quality of peripancreatic blood vessels and the clinical value of low-keV imaging in enhancing the image quality of peripancreatic arteriovenous vessels.We prospectively enrolled 103 patients who underwent abdominal vascular-enhanced CT examinations at the Affiliated Hospital of Hebei University between December 2022 and May 2023 and who were all scanned with the dual-energy feature on the United Imaging ATLAS scanner. The images were reconstructed at 70 keV, mixed energy, and optimized single energy in the post-processing station of United Imaging Healthcare Technology Co., Ltd. The CT value and contrast-to-noise ratio (CNR) of the superior mesenteric artery (SMA), gastroduodenal artery (GDA), inferior pancreaticoduodenal artery (IPDA), and superior mesenteric vein (SMV) were compared across energy levels, and then the image quality was subjectively evaluated. One-way analysis of variance and rank-sum tests were utilized for the statistical analysis.The CT values of SMA, GDA, IPDA, and SMV in the optimal single energy group were 358.37±70.24, 323.36±88.23, 300.76±76.27, and 257.74±20.56 Hounsfield unit (HU), respectively, which were superior to those in the mixed energy (241.66±47.69, 235.17±53.71, 207.36±45.17, and 187.39±23.21 HU) and 70 keV groups (260.89±54.27, 252.41±58.87, 223.17±43.65, and 203.18±18.17 HU) (P<0.05). The diagnostic efficacy was greater in the optimal single energy group than in the other 2 groups (4.63±0.50, 3.91±0.57, and 4.23±0.83) (P<0.05).The optimal single energy for showing peripancreatic blood vessels is 62±7 keV when utilizing single-energy spectral CT imaging.2024 Quantitative Imaging in Medicine and Surgery. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2024]版:
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2024版] 出版当年五年平均 出版前一年[2023版]

第一作者:
第一作者机构: [1]Department of Radiology, Affiliated Hospital of Hebei University, Baoding, China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of Radiology, Affiliated Hospital of Hebei University, Baoding, China. [*1]Department of Radiology, Affiliated Hospital of Hebei University, No. 212 of Yuhua East Road, Lianchi District, Baoding 071000, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号