高级检索
当前位置: 首页 > 详情页

Comparative analysis of radiation dose and image quality between organ dose modulation and 3D smart mA modulation during head-neck CT angiography

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ EI

机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding City, Hebei, Peoples R China [2]Hebei Univ, Med Sch, Baoding City, Hebei, Peoples R China [3]Hebei Gen Hosp, Dept Radiol, Shijiazhuang, Hebei, Peoples R China
出处:
ISSN:

关键词: Organ dose modulation 3D smart mA modulation radiation dose image quality head-neck CT angiography

摘要:
OBJECTIVE: To assess the difference in absorbed organ dose and image quality for head-neck CT angiography using organ dose modulation compared with 3D smart mA modulation in different body mass indices (BMIs) using an adaptive statistical iterative reconstruction (ASiR-V) algorithm. METHODS: Three hundred patients underwent head-neck CTA were equally divided into three groups: A (18.5 kg/m(2) <= BMI < 24.9 kg/m(2)), B (24.9 kg/m(2) <= BMI < 29.9 kg/m(2)) and C (29.9 kg/m(2) <= BMI <= 34.9 kg/m(2)). The groups were randomly subdivided into two subgroups (n = 50): A1-A2, B1-B2 and C1-C2. The patients in subgroups A1, B1 and C1 underwent organ dose modulation with the ASiR-V algorithm, while other patients underwent 3D smart mA modulation. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of all head-neck CT angiography images were calculated. Images were then subjectively evaluated. Mean values of several indices including dose-length product (DLP) were computed. The DLP was converted to the effective dose (ED). SNR, CNR and ED in groups A, B, and C were compared in statistical data analysis. RESULTS: SNR, CNR, and subjective image scores show no statistical differences in three groups (P > 0.05). However, there is significant difference of ED values (P < 0.05). For example, in subgroup A1 mean ED values are 15.30% and 23.66% lower than those in subgroup A2 at thyroid gland and eye lens, respectively. Similar patterns also exist in groups B (B1 vs. B2) and C (C1 vs. C2). CONCLUSIONS: Using organ dose modulation and applying the ASiR-V algorithm can more effectively reduce the radiation dose in head-neck CT angiography than using 3D smart mA modulation, while maintaining image quality. Thus, using organ-based dose modulation has the additional benefit of reducing dose to the thyroid gland and eye lens.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 仪器仪表 4 区 光学 4 区 物理:应用
JCR分区:
出版当年[2019]版:
Q3 PHYSICS, APPLIED Q3 INSTRUMENTS & INSTRUMENTATION Q4 OPTICS
最新[2023]版:
Q3 INSTRUMENTS & INSTRUMENTATION Q3 OPTICS Q3 PHYSICS, APPLIED

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding City, Hebei, Peoples R China [*1]Hebei Univ, Affiliated Hosp, 212 Yuhua East Rd, Baoding City 071000, Hebei, Peoples R China
通讯作者:
通讯机构: [1]Hebei Univ, Dept Radiol, Affiliated Hosp, Baoding City, Hebei, Peoples R China [*1]Hebei Univ, Affiliated Hosp, 212 Yuhua East Rd, Baoding City 071000, Hebei, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:4 总访问量:960 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号