Optimal Monochromatic Imaging of Spectral Computed Tomography Potentially Improves the Quality of Hepatic Vascular Imaging

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Dept CT & MRI, Affiliated Hosp, Baoding 071002, Peoples R China [2]Shijiazhuang First Hosp, Dept Med Res, 36 Fanxi Rd, Shijiazhuang 050011, Hebei, Peoples R China [3]Hebei Med Univ, Hosp 2, Shijiazhuang 050011, Hebei, Peoples R China
出处:
ISSN:

关键词: Liver Spectral CT CT angiography Monochromatic image Image optimization

摘要:
Objective: To investigate the efficiency of spectral computed tomography (CT) optimal monochromatic images in improving imaging quality of liver vessels. Materials and Methods: The imaging data of 35 patients with abdominal CT angiography were retrospectively analyzed. Hepatic arteries, portal veins, and hepatic veins were reconstructed with mixed energy (quality check, QC), 70 keV and optimal monochromatic mode. Comparative parameters were analyzed including CT value, image noise (IN), contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and subjective qualitative analysis. Results: The optimal monochromatic value for assessment of the common hepatic artery, portal vein, and hepatic vein ranged between 49 keV and 53 keV, with a mean of 51 keV. There were statistically significant differences (p < 0.001) among the optimal monochromatic, 70 keV and QC images with regards to the hepatic vascular CT value, IN, CNR, SNR, and subjective qualitative score. CNR of the common hepatic artery in the optimal monochromatic, 70 keV and QC groups was 24.6 +/- 10.9, 18.1 +/- 8.3, and 11.6 +/- 4.6, respectively (p < 0.001) with subjective scores of 4.7 +/- 0.2, 4.0 +/- 0.3, and 3.6 +/- 0.4, respectively (p < 0.001). CNR of the hepatic portal vein was 6.9 +/- 2.7, 4.3 +/- 1.9, and 3.0 +/- 2.1, respectively (p < 0.001) with subjective scores of 4.5 +/- 0.3, 3.9 +/- 0.4, and 3.3 +/- 0.3, respectively (p < 0.001). CNR of the hepatic vein was 5.7 +/- 2.3, 4.2 +/- 1.9, and 2.7 +/- 1.4, respectively with subjective scores of 4.3 +/- 0.3, 3.8 +/- 0.4, and 3.2 +/- 0.3, respectively (p < 0.001). Conclusion: Optimal monochromatic images can lead to improvement in the imaging parameters and optimization of the image quality of the common hepatic artery, hepatic portal vein and hepatic vein compared with conventional mixed kV and with 70 keV datasets.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2019]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
JCR分区:
出版当年[2018]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2018版] 出版当年五年平均 出版前一年[2017版] 出版后一年[2019版]

第一作者:
第一作者机构: [1]Hebei Univ, Dept CT & MRI, Affiliated Hosp, Baoding 071002, Peoples R China
共同第一作者:
通讯作者:
通讯机构: [2]Shijiazhuang First Hosp, Dept Med Res, 36 Fanxi Rd, Shijiazhuang 050011, Hebei, Peoples R China [*1]Department of Medical Research, Shijiazhuang First Hospital, 36 Fanxi Road,Shijiazhuang 050011, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号