Integration of Diaphragmatic Ultrasonography and Intra-Abdominal Pressure Measurement for Optimizing Weaning from Mechanical Ventilation

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ SSCI

机构: [1]Hebei Univ, Affiliated Hosp, Intens Care Unit, 212 Yuhua Rd,Lianchi Dist, Baoding 071000, Hebei, Peoples R China [2]Hebei Univ, Affiliated Hosp, Dept Hepatobil Surg, 212 Yuhua Rd,Lianchi Dist, Baoding 071000, Hebei, Peoples R China
出处:
ISSN:

关键词: diaphragmatic ultrasonography IAP intra-abdominal pressure MV mechanical ventilation

摘要:
Objective: The objective of this study was to evaluate the effectiveness of diaphragmatic ultrasonography in conjunction with intra-abdominal pressure (IAP) measurement for assessing diaphragm function and determining the optimal timing for weaning from mechanical ventilation (MV). Methods: A cohort of 100 patients undergoing MV at the intensive care department of the Affiliated Hospital of Hebei University between January 2023 and July 2023 was enrolled. Spontaneous breathing trials (SBTs) were performed once patients met the weaning criteria. At the 30-minute mark of the SBT, diaphragmatic ultrasonography and IAP measurements were conducted. Based on weaning outcomes, patients were categorized into successful and failed weaning groups. Diaphragmatic excursion (DE), diaphragm thickening fraction (TFdi), diaphragmatic rapid shallow breathing index (D-RSBI), and IAP were compared between groups. The predictive value of these parameters in determining optimal weaning timing was analyzed using receiver operator characteristic (ROC) curves. Results: Compared to the failed weaning group, the successful weaning group exhibited significantly lower values of D-RSBI and IAP values along with higher values of DE, TFdi, diaphragm thickness at end-inhalation (DTei), and diaphragm thickness at end-exhalation (DTee) (p < 0.05). In the single-parameter analysis, the area under the curve (AUC) values for D-RSBI, DE, TFdi, and IAP were 0.880 (95% CI: 0.811- 0.948), 0.981 (95% CI: 0.960- 1.000), 0.907 (95% CI: 0.872- 0.972), and 0.838 (95% CI: 0.748- 0.929), respectively. The optimal cut-off values were 13.5 breaths /(min*cm), 1.2 cm, 29.3%, and 5.6 mmHg, respectively. In combined parameter analysis, the combination of IAP and DE demonstrated the highest predictive accuracy. Conclusion: The integration of diaphragmatic ultrasonography with IAP measurement is an effective approach for predicting weaning outcomes in patients undergoing MV. This combined assessment may assist clinicians in optimizing weaning strategies and improving patient outcomes.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2026]版:
最新[2025]版:
大类 | 3 区 医学
小类 | 4 区 卫生保健与服务 4 区 卫生政策与服务
JCR分区:
出版当年[2025]版:
最新[2023]版:
Q2 HEALTH CARE SCIENCES & SERVICES Q2 HEALTH POLICY & SERVICES

影响因子: 最新[2023版] 最新五年平均 出版当年[2025版] 出版当年五年平均 出版前一年[2024版]

第一作者:
第一作者机构: [1]Hebei Univ, Affiliated Hosp, Intens Care Unit, 212 Yuhua Rd,Lianchi Dist, Baoding 071000, Hebei, Peoples R China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15716 今日访问量:0 总访问量:1038 更新日期:2025-06-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号