Asymmetrical flow field-flow fractionation coupled with multi-detector: A robust method for evaluating the degradation of jujube polysaccharides with ultrasound-assisted H2O2 and subsequent conjugation with soybean 7S globulin
机构:[1]Key Laboratory of Pathogenesis Mechanism and Control of Inflammatory-Autoimmune Disease of Hebei Province, School of Basic Medical Sciences, Hebei University, Baoding 071000, China[2]Key Laboratory of Public Health Safety of Hebei Province, College of Public Health, Hebei University, Baoding 071000, China[3]Medical Comprehensive Experimental Center, Hebei University, Baoding 071000, China[4]Clinical Laboratory, Affiliated Hospital of Hebei University, Baoding 071000, China河北大学附属医院[5]State Key Laboratory of New Pharmaceutical Preparations and Excipients, Hebei University, Baoding 071002, China[6]Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Hebei University, Baoding 071002, China
The authors acknowledge the support provided by the Natural Science
Foundation of Hebei Provide (H2024201027), the Hebei Province
Key Research Projects (22372505D, 202360102030020), the Interdisciplinary
Research Program of Natural Science of Hebei University
(DXK202115), and the Program of Innovation Ability Improvement of
Baoding (2211N012).
第一作者机构:[1]Key Laboratory of Pathogenesis Mechanism and Control of Inflammatory-Autoimmune Disease of Hebei Province, School of Basic Medical Sciences, Hebei University, Baoding 071000, China
共同第一作者:
通讯作者:
通讯机构:[1]Key Laboratory of Pathogenesis Mechanism and Control of Inflammatory-Autoimmune Disease of Hebei Province, School of Basic Medical Sciences, Hebei University, Baoding 071000, China[5]State Key Laboratory of New Pharmaceutical Preparations and Excipients, Hebei University, Baoding 071002, China[6]Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of Ministry of Education, Hebei University, Baoding 071002, China
推荐引用方式(GB/T 7714):
Li Jiaqi,Zhang Xirui,Lian Haichen,et al.Asymmetrical flow field-flow fractionation coupled with multi-detector: A robust method for evaluating the degradation of jujube polysaccharides with ultrasound-assisted H2O2 and subsequent conjugation with soybean 7S globulin[J].Food Chemistry.2025,464:141609.doi:10.1016/j.foodchem.2024.141609.
APA:
Li Jiaqi,Zhang Xirui,Lian Haichen,Zhang Chenjing,Zheng Hailiang...&Dou Haiyang.(2025).Asymmetrical flow field-flow fractionation coupled with multi-detector: A robust method for evaluating the degradation of jujube polysaccharides with ultrasound-assisted H2O2 and subsequent conjugation with soybean 7S globulin.Food Chemistry,464,
MLA:
Li Jiaqi,et al."Asymmetrical flow field-flow fractionation coupled with multi-detector: A robust method for evaluating the degradation of jujube polysaccharides with ultrasound-assisted H2O2 and subsequent conjugation with soybean 7S globulin".Food Chemistry 464.(2025):141609