Rapid extraction of osimertinib and its active metabolite in urine by miniaturized centrifugal spin-column extraction using ionic liquid hybrid hierarchical porous adsorbent

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Coll Pharmaceut Sci, Sch Life Sci, Minist Educ,Key Lab Med Chem & Mol Diag,State Key, Baoding 071002, Peoples R China [2]Hebei Univ, Coll Publ Hlth, Hebei Key Lab Publ Hlth Safety, Baoding 071002, Peoples R China [3]Hebei Univ, Affiliated Hosp, Dept Pharm, Baoding 071002, Peoples R China
出处:
ISSN:

关键词: Osimertinib AZ-5104 Miniaturized centrifugal spin-column extraction Liquid Chromatography Ionic liquid hybrid hierarchical porous adsorbent

摘要:
Osimertinib (OSIM) is widely used as a mainstream drug for the treatment of non-small cell lung cancer (NSCLC). However, the lack of a rapid extraction and detection method for OSIM and its metabolite, AZ-5104, has limited clinical drug metabolism and drug resistance research because the drug is unstable. In this study, a new ionic liquid hybrid hierarchical porous material (IL-HHPM) was synthesized with hierarchical porous structures, including micropores (1.6-2.0 nm), mesopores (2.0-50.0 nm), macropores (50.0-148.7 nm), and multiple functional groups via a one-step hydrothermal method using silanized ionic liquids (IL) as functionalized hybrid monomer. The IL-HHPM has the advantages of a high specific surface area (437.4 & PLUSMN; 4.6 m2 g-1), sizable pore volume (0.74 cm3 g-1), and fast mass transfer, additionally, the IL-HHPM adsorbed OSIM and AZ-5104 via & pi;-& pi; interactions and hydrogen bonding. OSIM and AZ-5104 were rapidly extracted and measured in human urine using rapid and miniaturized centrifugal spin-column extraction (MCSCE), which was based on the IL-HHPM. The optimized factors for the extraction recoveries of OSIM and AZ-5104 were adsorbent dosage (8.0 mg), sample volume (0.5 mL), and operation time (9.0 min), and markedly reduced the adsorbent dosage and operation time. The IL-HHPM-MCSCE-HPLC method displayed good linearity (0.02-5.00 & mu;g mL-1, r & GE; 0.9997), satisfying accuracy (spiked recoveries of 87.7%-100.0%), and good precision (RSDs & LE; 7.0%). The developed method is rapid, sensitive, and reproducible for the simultaneous determination of trace level of OSIM and AZ -5104 in human urine.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2025]版:
大类 | 2 区 化学
小类 | 1 区 生化研究方法 2 区 分析化学
最新[2025]版:
大类 | 2 区 化学
小类 | 1 区 生化研究方法 2 区 分析化学
JCR分区:
出版当年[2023]版:
Q1 BIOCHEMICAL RESEARCH METHODS Q1 CHEMISTRY, ANALYTICAL
最新[2023]版:
Q1 BIOCHEMICAL RESEARCH METHODS Q1 CHEMISTRY, ANALYTICAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2023版] 出版当年五年平均 出版前一年[2022版]

第一作者:
第一作者机构: [1]Hebei Univ, Coll Pharmaceut Sci, Sch Life Sci, Minist Educ,Key Lab Med Chem & Mol Diag,State Key, Baoding 071002, Peoples R China [2]Hebei Univ, Coll Publ Hlth, Hebei Key Lab Publ Hlth Safety, Baoding 071002, Peoples R China
通讯作者:
通讯机构: [1]Hebei Univ, Coll Pharmaceut Sci, Sch Life Sci, Minist Educ,Key Lab Med Chem & Mol Diag,State Key, Baoding 071002, Peoples R China [2]Hebei Univ, Coll Publ Hlth, Hebei Key Lab Publ Hlth Safety, Baoding 071002, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

相关文献

资源点击量:15101 今日访问量:4 总访问量:964 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号