Effects of full-threaded headless cannulated compression screws and anatomical plates on the efficacy, safety, and prognosis of patients with triplane fractures of the distal tibia

| 认领 | 导出 |

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ Engn, Affiliated Hosp, Dept Orthoped 2, 81 Congtai Rd, Handan 056002, Hebei, Peoples R China [2]Handan Cent Hosp, Prehosp Emergency, Handan 056001, Hebei, Peoples R China [3]Handan Cent Hosp, Dept Neurol Surg, Handan 056001, Hebei, Peoples R China
出处:
ISSN:

关键词: Full-threaded headless cannulated compression screws anatomical plate triplane fractures of distal tibia efficacy prognosis

摘要:
Objective: To compare the clinical efficacy, safety, and prognosis of full-threaded headless cannulated compression screws (HCCSs) and anatomical plates (APs) in the treatment of triplane fractures of the distal tibia. Methods: In this retrospective study, 74 patients with triplane fractures of the distal tibia treated in our hospital from April 2017 to March 2019 were selected as the research subjects. Among them, 38 patients receiving full-threaded HCCSs were assigned to the research group (RG), and the remaining 36 patients receiving APs were assigned to the control group (CG). The general indices, including operation, fracture healing, and ambulation times, efficacy, and complications were recorded and compared between the two groups. Visual analogue scale (VAS) was applied to assess pain, and a quality of life (QOL) survey was conducted at 6 months after surgery. Results: Compared with the CG, the operation time, fracture healing time, and ambulation time of the RG were significantly shortened (P<0.05). The proportion of patients with excellent and good outcomes and Mazur Scores in the RG were higher than those in the CG (P<0.05). The frequency of complications in the RG was lower than that in the CG (P<0.05). The preoperative VAS score did not exhibit significant differences between the two groups (P<0.05), but the scores in the RG at T1 and T2 were significantly lower than those in the CG (P<0.001). The QOL score in the RG (76.17 +/- 8.57) was also significantly higher than in the CG (7154 +/- 8.02)(P<0.05). Conclusion: Full-threaded HCCSs are more effective and safer than APs and can effectively improve the prognosis of patients with triplane fractures of the distal tibia.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验 4 区 肿瘤学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验 4 区 肿瘤学
JCR分区:
出版当年[2022]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL Q4 ONCOLOGY
最新[2023]版:
Q3 MEDICINE, RESEARCH & EXPERIMENTAL Q4 ONCOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Hebei Univ Engn, Affiliated Hosp, Dept Orthoped 2, 81 Congtai Rd, Handan 056002, Hebei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:0 总访问量:960 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号