摘要:
Objective: To compare application value between Contrast-Enhanced Ultrasound (CEUS) and conventional ultrasound in preoperative and staging diagnosis of cervical cancer patients. Methods: CEUS and conventional ultrasound were used respectively for preoperative diagnosis of 126 cases of cervical cancer collected from our Hospital. A comparison was made for lesion sizes and ranges of cervical cancer as well as diagnostic results of different stages achieved through the two diagnostic methods. In this study, all the operations were approved by the hospital's ethics committee. Results: The cervical cancer lesion area (2328.18 +/- 1153.06 mm(2)), cervical cancer lesion long diameter (51.09 +/- 13.25 mm), and cervical cancer lesion anteroposterior diameter (42.56 +/- 13.29 mm) displayed through CEUS were significantly better than the cervical cancer lesion area (1667.69 +/- 943.34 mm(2)), cervical cancer lesion long diameter (44.49 +/- 13.42 mm), and cervical cancer lesion anteroposterior diameter (36.06 +/- 13.47 mm) through conventional ultrasound, which was statistically significant (P <0.05); the detection rates of stage I cervical cancer (85.18%) and stage II cervical cancer (92.98%) and the total detection rate (93.65%) achieved by CEUS were greatly superior to those of stage I (0.00%) and stage II (36.84%) and the total detection rate (50.00%) by conventional ultrasound, which was statistically significant (P <0.05); while comparison of stage III and stage IV detection rates was statistically insignificant (P >0.05). Conclusion: Compared with conventional ultrasound, CEUS is more valuable in preoperative and staging diagnosis of cervical cancer patients as it can show lesion locations more clearly and has higher detection rates.

语种:
被引次数:
WOS:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
JCR分区:
出版当年[2016]版:
Q4 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版]

第一作者:
第一作者机构: [1]Hebei Univ, Affiliated Hosp, Dept Ultrasound, Baoding, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15101 今日访问量:2 总访问量:962 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号