Effect of 18F-FDG PET/CT Imaging Combined with 3D-Printed Templates on Biopsy Efficacy in Patients with Lung Tumor

文献详情

资源类型:
Pubmed体系:
机构: [1]Jianyang Zhang, Nuclear Medicine Department, Baoding NO.1 Central Hospital, Baoding 071000, Hebei, China. [2]Cheng Ran, E.N.T. Department, Affiliated Hospital of Hebei University, Baoding 071000, Hebei, China. [3]Jing Chen, Nuclear Medicine Department, Baoding NO.1 Central Hospital, Baoding 071000, Hebei, China. [4]Huimin Song, Nuclear Medicine Department, Baoding NO.1 Central Hospital, Baoding 071000, Hebei, China. [5]Xianbo Li, Thoracic Surgery Department, Baoding NO.1 Central Hospital, Baoding 071000, Hebei, China.
出处:
ISSN:

关键词: 18F-FDG PET/CT 3D-Printed Templates Percutaneous Aspiration Biopsy Lung Diagnostic Efficacy

摘要:
To investigate the effect of 18F-FDG PET/CT imaging combined with 3D-printed templates on the biopsy results and diagnostic efficacy in patients with lung tumors.This was a comparative study. A total of 80 patients with suspected lung tumors admitted to Baoding NO.1 Central Hospital from May 2022 to December 2023 were selected as the research subjects and divided into the study group and the control group per different detection methods. Patients in the control group were treated with 18F-FDG PET/CT imaging-guided percutaneous aspiration biopsy of the lung, while those in the observation group underwent 18F-FDG PET/CT imaging-guided percutaneous aspiration biopsy of the lung combined with 3D printed templates. Afterward, the biopsy results of the two groups and their diagnostic efficacy and complications were compared.No significant differences were observed in tissue length and scanning time between the two groups (P>0.05). The operation time and number of biopsies in the observation group were less than those in the control group, with significant differences (P<0.05). Meanwhile, there was no statistically significant difference in specificity (15.00% vs. 27.50%) and misdiagnosis rate (2.50% vs. 10.00%) between the two groups (P>0.05). Moreover, the incidence of complications in the observation group was 5.00%, lower than the control group (7.50%), with no statistically significant differences (χ²=0.213, P=0.644).The observation group was found to have superior effect than control group, with fewer punctures and shorter puncture time, making it worthy of promotion in clinical application.Copyright: © Pakistan Journal of Medical Sciences.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2026]版:
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
第一作者:
第一作者机构: [1]Jianyang Zhang, Nuclear Medicine Department, Baoding NO.1 Central Hospital, Baoding 071000, Hebei, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15101 今日访问量:4 总访问量:964 更新日期:2025-05-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 河北大学附属医院 技术支持:重庆聚合科技有限公司 地址:保定市莲池区裕华东路212号