Optical coherence tomography versus intravascular ultrasound in patients with myocardial infarction: a diagnostic performance study of pre-percutaneous coronary interventions

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Hebei Univ, Affiliated Hosp, Color Ultrason Room, Baoding, Hebei, Peoples R China [2]Handan Shengji Tumor Hosp, Dept Cardiol, Handan, Hebei, Peoples R China [3]First Cent Hosp Baoding, Color Ultrason Room, Baoding, Hebei, Peoples R China
出处:
ISSN:

关键词: Frequency domain optical coherence tomography Intravascular ultrasound Myocardial infarction Percutaneous coronary intervention Quantitative coronary angiography

摘要:
Accurate coronary measurements are important in guiding percutaneous coronary intervention. Intravascular ultrasound is a widely accepted diagnostic modality for coronary measurement before percutaneous coronary intervention. The spatial resolution of optical coherence tomography is 10 times larger than that of intravascular ultrasound. The objective of the study was to compare quantitative and qualitative parameters of frequency domain optical coherence tomography (FDOCT) with those of intravascular ultrasound and coronary angiography in patients with acute myocardial infarction. Diagnostic parameters of coronary angiography, intravascular ultrasound, and FDOCT of 250 patients with coronary artery disease who required admission diagnosis were included in the analyses. Minimum lumen diameter detected by FDOCT was larger than that detected by quantitative coronary angiography (2.11 +/- 0.1 vs 1.89 +/- 0.09 mm, P <0.0001, q=34.67) but smaller than that detected by intravascular ultrasound (2.11 +/- 0.1 vs 2.19 +/- 0.11 mm, P <0.0001, q=12.61). Minimum lumen area detected by FDOCT was smaller than that detected by intravascular ultrasound (3.41 +/- 0.01 vs 3.69 +/- 0.01 mm(2), P <0.0001). FDOCT detected higher numbers of thrombus, tissue protrusion, dissection, and incomplete stent apposition than those detected by intravascular ultrasound (P <0.0001 for all). More accurate and sensitive results of the coronary lumen can be detected by FDOCT than coronary angiography and intravascular ultrasound .

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 3 区 生物学 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 生物学 4 区 医学:研究与实验
JCR分区:
出版当年[2020]版:
Q2 BIOLOGY Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 BIOLOGY Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Hebei Univ, Affiliated Hosp, Color Ultrason Room, Baoding, Hebei, Peoples R China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:15100 今日访问量:4 总访问量:960 更新日期:2025-04-01 建议使用谷歌、火狐浏览器 常见问题