机构:[1]Affiliated Hospital of Hebei University , Baoding City, Hebei, 071002, China河北大学附属医院[2]Biomedical Multidisciplinary Research Center of Hebei University, 180 Wusi East Road, Baoding City, Hebei, 071002, China[3]College of Mathematics and Computer Science, Hebei University, 180 Wusi East Road, Baoding City, Hebei, 071002, China[4]Biomedical Multidisciplinary Research Center of Hebei University, 180 Wusi East Road, Baoding City, Hebei, 071002, China
Image Guided Intervention for valvular heart disease is increasingly making progress in minimally invasive manner, where effective and accurate segmentation of aortic valve (AV) from echocardiography is fundamental to improve the intra operative location accuracy. This paper proposes a shape constraint Chan-Vese (CV) model for segmenting the AV from ultrasound (US) images. Considering the poor quality and speckle noise in AV US images, the problem of the overflow at the weak edge is solved by adding the shape constraint to the CV model. The predefined shape constructed from AV region is applied as an energy constraint to the energy function through a signed distance map, and the AV is detected from the US image by minimizing the energy function. A hundred AV segmentation results are analyzed in the experiment, where the evaluation parameters are 95.38 +/- 2.7%, 1.4 +/- 0.5 mm, 2.07 +/- 1.3 mm in transthoracic AV and 97.2 +/- 11.6%, 0.7 +/- 0.15 mm, 1.04 +/- 0.6 mm in transesophageal AV, which reveal that the shape constraint CV model can segment AV accurately, efficiently and robustly.
基金:
Chinese NSFC [61190120, 61190124, 61271318]; Hebei University Biomedical Multidisciplinary Research Center [BM201110]; Technological Innovation of Undergraduate [201210075008]; Hebei Province Education Youth Found [Q201223]; Hebei Province Health [20120399]
语种:
外文
被引次数:
WOS:
PubmedID:
第一作者:
第一作者机构:[1]Affiliated Hospital of Hebei University , Baoding City, Hebei, 071002, China
通讯作者:
推荐引用方式(GB/T 7714):
Dong Bin,Guo Yiting,Wang Bing,et al.Aortic Valve Segmentation from Ultrasound Images Based on Shape Constraint CV Model[J].2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC).2013,1402-1405.doi:10.1109/EMBC.2013.6609772.
APA:
Dong, Bin,Guo, Yiting,Wang, Bing&Gu, Lixu.(2013).Aortic Valve Segmentation from Ultrasound Images Based on Shape Constraint CV Model.2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC),,
MLA:
Dong, Bin,et al."Aortic Valve Segmentation from Ultrasound Images Based on Shape Constraint CV Model".2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) .(2013):1402-1405